Most of our induction heating machines are cooled by water, you can build the cooling system for our machines with tap water, water pump and water tank by yourself, we also provide different types of water chiller for you.
Induction heating machine requires water in high quality:
1. good quality water
2. enough pressure
3. small location room
4.Safe And Longtime working
Our water chiller can meet its strict requirements above and prolong your machine working life
It also good for any machines which are cooled by water.
CA series chiller specifications:
1.COPELAND compressor,hermetic scroll type,features low noise,low vibration,high efficiency and low energy consumption.
2.Environment-friendly refrigerant,such as R407c,R404a which is no harm to the ozone layer.
3.SCHNEIDER brand electric components will ensure the machine running stably.
4.Imported stainless steel water pump,featuring wide working range,low noise,reliable performance,no leaking and maintenance free.
5.High quality stainless steel tank and pipelines will ensure the water quality and easy to clean maintain.
6.Electric static spraying enclosure,European design and elegant appearance.
working range:
The temperature range of chilled fluid is from 5 to 35degree celsius;
Temperature difference between inlet and outlet chilled fluid is from 3 to 8 degree celsius.
It is better to use the chiller while the ambient temperature at or below 35 degree celsius.
                 CA Series Air cooled industrial chiller |  | ||||||||||
                  Mode Item |
CA-0.6 | CA-1 | CA-2 | CA-3 | CA-4 | CA-5 | CA-6 | CA-8(D) | CA-10(D) | Â | |
nominal cooling capacity | Kcal/h 50HZ/60HZ |
1290 1548 |
2451 2941 |
4446 5332 |
6803 8163 |
8815 10578 |
11223 13468 |
13115 15738 |
17630 21156 |
22446 26935 |
 |
 | |||||||||||
KW 50HZ/60HZ |
1.5 1.8 |
2.85 3.42 |
5.17 6.2 |
7.91 9.5 |
10.25 12.3 |
13.05 15.66 |
15.25 18.3 |
20.5 24.6 |
26.1 31.3 |
 | |
 | |||||||||||
Total input power | KW | 0.96 | 1.46 | 2.25 | 3.27 | 4.57 | 5.54 | 6.33 | 8.29 | 10.47 | Â |
Power supply voltage | 1PH~220V 50HZ(60HZ) | 3PH 380V 50HZ(220V/415V/480VÂ Â 50HZ/60HZ) | Â | ||||||||
(110V 50HZ/60HZ) | Â | ||||||||||
Refrigerant | Type | R22(R134a/R407C) | Â | ||||||||
Control mode | Capillary | Expansion valve | Â | ||||||||
Compressor | Type | Hermetic rotating type | Hermetic scroll type(Piston) |  | |||||||
Power(KW) | 0.45 | 0.95 | 1.73 | 2.7 | 3.52 | 4.41 | 5.2 | 3.52× 2 | 4.41× 2 |  | |
Condenser | Type | High efficient finned copper tube+ low noise outer rotor fan | Â | ||||||||
Cooling Air volume(m 3 /h) | 750 | 1000 | 2000 | 3000 | 4000 | 5000 | 6000 | 8000 | 10000 | Â | |
Evaporator | Type | Water tank with coil(Shell and Tube) | Â | ||||||||
Chilled fluid flow(m 3 /h) | 0.258 0.31 |
0.49 0.589 |
0.89 1.068 |
1.36 1.63 |
1.76 2.11 |
2.24 2.68 |
2.63 3.15 |
3.52 4.22 |
4.47 5.37 |
 | |
 | |||||||||||
Tank volume(L) | 16 | 20 | 25 | 50 | 60 | 70 | 70 | 120 | 200 | Â | |
inlet/outlet pipe caliber | 1" | 1" | 1" | 1" | 1" | 1" | 1" | 1-1/2" | 1-1/2" | Â | |
Water pump | Power(kw) | 0.37 | 0.37 | 0.37 | 0.37 | 0.75 | 0.75 | 0.75 | 0.75 | 0.75 | Â |
Pump head(m) | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 22 | 20 | Â | |
Safty protection | Compressor overheating, over current, high and low pressure, over temperature, flow switch, phase sequence, phase-missing, exhaust overheating, anti-freezing. | Â | |||||||||
Dimension | L(mm) | 530 | 580 | 650 | 930 | 1000 | 1140 | 1140 | 1300 | 1530 | Â |
W(mm) | 440 | 440 | 500 | 520 | 560 | 560 | 560 | 720 | 780 | Â | |
H(mm) | 780 | 850 | 950 | 975 | 1070 | 1040 | 1040 | 1310 | 1430 | Â | |
Weight | Kg | 50 | 73 | 100 | 135 | 150 | 175 | 180 | 310 | 450 | Â |
Note:     1. nominal cooling capacity calculated according to:                                                                                                        Inlet/outlet chilled fluid temperature: 12degree/7degree  Inlet/outlet cooling air temperature: 30degree/35degree                                                        2. Working condition:     The temperature range of chilled fluid is from 5 to 35degree   Temperature difference between inlet and outlet chilled fluid is from 3 to 8degree,  It is better to run the chiller while the ambient temperature at or below 35degree. The above red parameters is for the particular voltage, which need to made accordingly.      We reserve the right to modify the above information without further notice. For more information about our machines, please contact us now for we support you well |
 |
Â
FAQ
Q: What's your advantage? Why we choose you?
A: 1,Our factory has produced the water chiller over 15 years,  we have rich experience in the production and design the water chiller technology machine for customers.
 2, Great production capacity Sustainable Supply . According to customer requirements, We support the customized including the packing
3,  We use 100% new materials and the striclty control for the  production process, in consequence our defective rate is lower than 0.01%
Q: How long is your delivery time?
A: Generally it is 5-10 days if the goods are in stock. or it is 15-20 days if the goods are not in stock, it is according to quantity.
Q: How about warranty
A: 12 Months
A: Sure, we double test all our machines before delivery
For more questions or details about us and our machines, please contact us as below,
Â
Â
Â
Cholift supplys a wide range of high performance pallet stackers,light-duty pallet stackers,Standard Hand Stacker,Semi-electric pallet stackers,Full-electric Pedestrian pallet stackers,Full-electric Platform Pallet Stackers,pallet stackers are perfect for placing goods into low to mid-level racking in a warehouse to suit every intensive or light operation, delivering reliability, energy efficiency, driver comfort, and low maintenance costs for the most demanding warehouse applications.
Semi Electric Stacker Truck,Semi Lift Truck Semi Electric Stacker,Semi Electric Stacker,Battery Powered Stacker
Ningbo Cholift Forklift Co.,Ltd , http://www.choliftchina.com